The pump should have flooded suction since it does not self prime. Filters
or restrictions should not be situated before the pump inlet. When priming,
operate the pump in short 10 second cycles to facilitate the clearing of air.
Ensure that there are no leaks or blockages in the associated pipework. The pump
should not be operated against a closed valve for longer than 30 seconds. Where
the pumped fluid causes coating or deposition, periodic cleaning of pumping
internals may be necessary. This can be achieved by flushing through with an
appropriate cleaning agent. The pump casing should be adequately ventilated to
avoid overheating the motor. The motor is protected by the Magnetic coupling
should the impeller stall. do not run the pump dry.